I. Pre-installation Preparation
1. Verify Parameters
- Check that the ball valve model, pressure rating, diameter, material, and temperature range are consistent with the working conditions.
- Confirm the flow direction indication (some require one-way sealing), and do not install in reverse.
2. Clean the Pipeline
- Remove welding slag, rust, and impurities from the pipeline to prevent scratching the valve seat sealing surface.
- The valve inner cavity also needs to be cleaned, without foreign objects or rust.
3. Check Integrity
- The ball body and valve seat should have no scratches or deformations; the sealing surface should be intact.
- The handle/actuator should rotate flexibly without sticking.
II. Installation Key Points
1. Installation Direction
- General ball valves can be installed at any angle, preferentially horizontally, for easy operation and maintenance.
- Ball valves with a drain/vent valve should have the drain port facing down or on the side for easy operation.
- Ball valves with flow direction markings, the medium flow direction must be consistent with the arrow.
2. Flange/Lug Connection
- Flange connection: The gasket should be centered, and bolts should be evenly tightened diagonally to prevent skewing and leakage.
- Threaded connection: Wrap the sealing tape appropriately and tighten moderately to avoid excessive force damaging the threads.
3. Welding Installation
- For welded ball valves, the valve should be in the fully open position when installed to prevent damage to the seal due to high temperature.
- Avoid splashing welding slag into the valve chamber. Allow it to cool naturally after welding.
4. Avoid Stress
- Install the valve after aligning the pipeline. Do not force the connection, as it may cause the valve body to crack.
- For large-diameter/high-pressure ball valves, install pipeline supports.
III. Operating and Usage Specifications
1. Opening and Closing Operation
- The ball valve only has two working positions: fully open and fully closed. Do not use it for throttling; it is prone to erosion of the seal.
- For handle-type: Parallel to the pipeline = fully open, vertical = fully closed.
- The operation should be smooth and light. Do not forcibly turn if there is sticking. Check for foreign objects or faults.
2. Operating Prohibitions
- Do not use an extension rod/pipe wrench to operate forcefully. It may damage the valve stem and actuator.
- Lock the ball valve as per regulations to prevent accidental operation.
- For gas, flammable, and explosive media, use fireproof structure ball valves. After installation, ensure proper static electricity grounding.
3. Daily Maintenance
- Regularly inspect for any leakage at the packing box and flange connection points.
- Regularly add lubricating grease to the valve stem to ensure smooth rotation.
- If the valve is not in use for a long time, open it once periodically to prevent sticking.
IV. Common Precautions
1. Ball valves are suitable for quick shut-off and not for regulating flow or pressure.
2. Select a wear-resistant hard-sealed ball valve for particles and fibers-containing media. Soft-sealed ball valves are prone to damage.
3. Use fireproof structure ball valves for gas, flammable, and explosive media. Ensure proper grounding after installation.
4. Before disassembly and repair, depressurize, cool down, and empty the medium. Do not disassemble under pressure.